翻訳と辞書
Words near each other
・ Network Driver Interface Specification
・ Network DVR
・ Network dynamics
・ Network economics
・ Network economy
・ Network effect
・ Network Effectiveness Ratio
・ Network element
・ Network emulation
・ Network Enabled Weapon
・ Network enclave
・ Network encryption cracking
・ Network engineering
・ Network enumeration
・ Network equipment provider
Network Equipment-Building System
・ Network era
・ Network Extrusion
・ Network File System
・ Network First
・ Network flow
・ Network for a New Culture
・ Network for Astronomy School Education
・ Network for Capacity Development in Nutrition
・ Network for Earthquake Engineering Simulation
・ Network for Education and Academic Rights
・ Network for Electronic Transfers
・ Network for Good
・ Network for Integrity in Reconstruction
・ Network for North Korean Democracy and Human Rights


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Network Equipment-Building System : ウィキペディア英語版
Network Equipment-Building System

NEBS (Network Equipment-Building System) describes the environment of a typical United States RBOC Central Office. NEBS is the most common set of safety, spatial and environmental design guidelines applied to telecommunications equipment in the United States. It is an industry requirement, but not a legal requirement.
NEBS was developed by Bell Labs in the 1970s to standardize equipment that would be installed in a central office. The objective was to make it easier for a vendor to design equipment compatible with a typical Regional Bell Operating Company (RBOC) central office (CO). This would result in lower development costs and ease the equipment's introduction into the network. Telcordia now manages the NEBS specifications. The four then-largest US Telecommunications companies (AT&T, Verizon, BellSouth, and Qwest) created the Telecommunications Carrier Group (TCG), a group formed to synchronize NEBS standards across the industry in the US. The TCG checklist specifies the individual NEBS requirements of each of its members in a matrix, making it simple to compare them.
==Levels==
"NEBS Level 1" means a very low threshold of equipment hazards and network degradation. NEBS Level 1 addresses the personnel and equipment safety requirements of (GR-63-CORE ) and (GR-1089-CORE ). Operability requirements are not enforced for NEBS Level 1 certification. It is primarily used for getting prototypes into lab trials. RBOCs require all equipment deployed by CLECs to be NEBS Level 1 certified.
"NEBS Level 2" addresses equipment operability in a controlled environment (usually datacenters) that will not be subjected to environmental stress. Because of ambiguity, this level of certification is rarely (if ever) used.
"NEBS Level 3" is a term from Bellcore special report, (SR-3580 ), and means the equipment meets all of the requirements of (GR-63-CORE ) and (GR-1089-CORE ). NEBS Level 3 has strict specifications for fire suppression, thermal margin testing, vibration resistance (earthquakes), airflow patterns, acoustic limits, failover and partial operational requirements (such as chassis fan failures), failure severity levels, RF emissions and tolerances, and testing/certification requirements.
''NOTE:''
# Verizon and AT&T do not follow NEBS Level 3 or SR-3580. They use their own NEBS checklist, (Verizon Checklist ) (in MS Word format) and (AT&T Checklist ), that details what they believe are important to their network's integrity. Both accept the TCG Checklist that can be found at those websites.